Verilink DIU2130 -- Configuration/Diagnostics --


The letter D is used on the Shelf/Slot map of the Top or Main Menu to represent a DIU2130 card. This card is a DSU which must be used in conjunction with a CSU card. The DIU2130 may be used with an NCC2020, SCC2020 or TAC2010 CSU card. Each DIU2130 is able to support one or two dataports. By selecting from various available rear interface cards, different synchronous serial interfaces may be supported. Up to 12 DIU2130 cards may be associated with a single CSU, allowing the design of a data channel bank.

The DIU configuration and diagnostics menu looks like:


       --- DIU 2130  CONFIGURATION/DIAGNOSTIC MENU ---



S) save config      Q) restore config      X) exit menu



C) CSU              [ 1,1 ]

T) timing source    CSU



   chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Dp)port 01 02 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..



   Lead Toggles     DTR)   DSR)   RTS)   CTS)   DCD)

   Forced Ports     1/-    1/-    1/-    1/-    1/-



                    Port 1     Port 2        Statistics

Mp) mode            64K        56K           FW/HW Rev...1.2/0.8

Sp) scram/hdlc inv  N/N        N/N           Battery.....OK

Kp) clocking        ST         ST            DTE Intf....V.35/V.35

Gp) LOS lead        NONE       NONE          Data bus....A



Ep) enable loop     YES        YES           Tp) test and monitor BEC

Np) near loopback   OFF        OFF           Pp) monitor leads and status

Fp) far loopback    OFF        OFF           A)  Alarm Enable...........YES
The lowercase p shown in some prompts is a variable. Use the number 1 or the number 2 in place of the p, depending which port you wish to option.