Verilink SCC Craft Port -- VIEW ALARM BUFFER --
Selecting View Alarm Buffer will result in a display of all
the alarm history information in the CSU memory. Here is a typical
output from that function:
[ 1, 1] Alarm: 208 Date: 04-21-97 Time: 15:45:09
(Near-End Network/Equipment UAS exceeded Cleared Alarm)
[ 1, 1] Alarm: 202 Date: 04-21-97 Time: 15:26:02
(Near-End Network/Equipment BER exceeded Cleared Alarm)
[ 1, 1] Alarm: 116 Date: 04-21-97 Time: 15:24:36
(Near-End Network/Equipment RAI Cleared Alarm)
[ 1, 1] Alarm: 218 Date: 04-21-97 Time: 15:24:35
(Near-End Network/Equipment LOF Cleared Alarm)
[ 1, 1] Alarm: 214 Date: 04-21-97 Time: 15:24:25
(Near-End Network/Equipment LOS Cleared Alarm)
[ 1, 1] Alarm: 224 Date: 04-21-97 Time: 15:24:25
(Near-End Equipment low density Cleared Alarm)
[ 1, 9] Alarm: 505 Date: 04-21-97 Time: 15:24:16
(Near-End Plug Present Alarm)
[ 1, 1] Alarm: 207 Date: 04-21-97 Time: 15:24:01
(Near-End Network/Equipment UAS exceeded Alarm)
[ 1, 1] Alarm: 201 Date: 04-21-97 Time: 15:24:01
(Near-End Network/Equipment BER exceeded Alarm)
[ 1, 1] Alarm: 217 Date: 04-21-97 Time: 15:23:55
(Near-End Network/Equipment LOF Alarm)
[ 1, 1] Alarm: 115 Date: 04-21-97 Time: 15:23:55
This information is volatile, it will be lost
if power to the CSU is lost.