Verilink SCC Craft Port -- DIU2131 --


The DIU2131 is represented by the letter L in the Shelf/Slot map area.

It is a DSU card which requires a CSU card to operate and is very much like the DIU2130. The difference is that the DIU2130 supports two high speed data ports while the DIU2131 supports one high speed V.35 data port (n x56K or n x64K) plus one low speed RS-232 port @ 1200 to 64K baud.

The single RS-232 data port handles synchronous data only and may be assigned to use any single timeslot on the CSU card with which it is associated. One DS0 is used for each DIU2131 RS-232 channel.

In order to use a DIU2131 the node must be controlled by an SCC card with version 1.81 or higher firmware. As of April 1997 no version of NCC firmware supports the DIU2131.

Once the user has navigated to the DIU2131 card the Configuration command may be used to do both configuration and diagnostic functions:


       --- DIU 2131  CONFIGURATION/DIAGNOSTIC MENU ---



S) save config      Q) restore config      X) exit menu



C) CSU              [ 1,1 ]

T) timing source    CSU



   chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Dp)port 01 01 01 01 01 01 01 01 01 01 01 01 .. .. .. .. .. .. 02 .. .. .. .. ..



   Lead Toggles     DTR)   DSR)   RTS)   CTS)   DCD)

   Forced Ports     1/-    1/-    1/-    1/-    1/-



                    Port 1     Port 2        Statistics

Mp) mode            64K        19.2K         FW/HW Rev...1.3/0.8

Sp) scram/hdlc inv  N/N        N/N           Battery.....OK

Kp) clocking        ST         ST            DTE Intf....V.35/RS-232

Gp) LOS lead        NONE       NONE          Data bus....A



Ep) enable loop     YES        YES           Tp) test and monitor BEC

Np) near loopback   OFF        OFF           Pp) monitor leads and status

Fp) far loopback    OFF        OFF           A)  Alarm Enable...........NO      






Return to SCC Craft Tutorial